ما توصّل إليه النقاش

  • The Teradek Bolt uses a 2-pin LEMO connector with pin 1 as ground, while some other devices like the Bartech use pin 1 as hot power, making cables between them incompatible and potentially damaging if swapped.
  • Connecting a reverse-polarity cable to the Bolt receiver can cause the positive voltage to appear on the BNC connector shells, which shorts when touching the grounded monitor BNC, triggering battery protection shutdown.
  • The Teradek Bolt power input specification of 6-28V indicates voltage range capability, not the reason for battery failures in this case.
  • A multimeter should be used to verify PTAP-LEMO cable polarity before connecting to equipment.
  • The Bolt appears to have reverse-polarity protection, while the Bartech does not and can be permanently damaged by incorrect polarity.

يعتمد على

  • The thread does not confirm whether the original Bolt factory cable was indeed reverse-polarity or whether user error occurred.
  • Reverse-polarity protection status of the Bolt is stated as uncertain for one contributor.
  • The discussion occurred in 2013 and may not reflect current product designs.