2012منتدى Monitors
TB6 monitor buttons unresponsive and CH1 label visible after moisture exposure
مضى على هذا 14 سنة. قد تكون المعدات والأسعار قد تغيّرت منذ ذلك الحين.
ما توصّل إليه النقاش
- A TB6 monitor exposed to rain may develop unresponsive buttons and display a CH1 label overlay across the image.
- Opening the TB6 casing by removing approximately eight Phillips screws and allowing internal components to dry through natural evaporation can restore normal button function.
- After moisture has evaporated and the casing is reassembled, the monitor can return to normal operation.
يعتمد على
- Solution is anecdotal from a single case in 2012.
- The underlying cause of button malfunction from moisture was not definitively identified.
- No information provided on whether the CH1 label issue resolves automatically or requires additional steps.