SteadiHub
2016General Discussion forum

Routing SDI cable through an old Flyer Steadicam top plate without complete disassembly

What the thread found

  • A thin SDI cable can be threaded through the post and top plate assembly without removing the small pins that hold the top plate together.
  • Reassembling the complete top plate and using thin HD-SDI rated cable with quality BNC connectors is the recommended approach for a proper installation.
  • Routing cable through without disassembly may cause tightness at extreme edges of side-to-side balancing movement and risks cable damage over time.

Depends on

  • The solution applies specifically to older Flyer Steadicam models.
  • Photographs that would have shown the exact configuration were not successfully attached to the original discussion.
  • The threaded approach is described as potentially temporary, with spare cables needed for replacement.
  • Success may depend on cable thickness and the specific configuration of individual units.
Read the original threadAsk about this threadThe answer cites the archive