Preparing a Steadicam EFP system for use after extended storage

What the thread found

  • Inspect all BNC and Hirose connectors for corrosion and verify signal integrity on all lines.
  • Clean and lubricate arm trunnions individually following a detailed procedure.
  • Clean and lubricate gimbal bearings, though this may be unnecessary if the new owner plans to replace the gimbal with a modern one.
  • Check arm cables for straightness and fraying.
  • Verify that the Anton/Bauer mount is secure.
  • Assemble and operate the complete rig briefly to identify cracked plastic parts and assess arm condition and operation.
  • Have someone experienced verify the vest condition.
  • EFP arm dog bones may be thinner than standard IIIA arm dog bones, which affects spring upgrade compatibility.

Depends on

  • The specific procedure for cleaning and lubricating arm trunnions was not provided in the discussion.
  • No local service providers in Chicago were identified.
  • EFP gimbal bearing maintenance may be unnecessary depending on the buyer's plans for the system.
  • Uncertainty remains about exact specifications of EFP arm dog bones compared to IIIA arms.