2008Batteries/Power forum

Dionic 90 battery flashing display under high current draw with Genesis camera and recorder

18 years old. Gear and prices may have changed since.

What the thread found

  • The Dionic 90 battery has a maximum current draw rating of 7 amperes, and the display will flash to alert the user when this threshold is exceeded.
  • A Genesis camera drawing approximately 60 watts combined with an SRW-1 recorder drawing approximately 55 watts results in total power consumption of around 115 watts or 8 amperes, which exceeds the Dionic 90 rating.
  • When combining a Genesis camera with onboard recorder and accessories, the power demand typically exceeds what a single Dionic 90 can safely supply.
  • For high-power applications like Genesis with recorder, the Dionic HC battery is a more appropriate choice than the Dionic 90.
  • A malfunctioning Dionic 90 that does not charge in any charger and displays strange flashing patterns on the real-time display may have failed electronics or cells and should be sent to the manufacturer for evaluation.

Depends on

  • The power consumption figures for Genesis and SRW-1 recorder are estimates provided by one participant and may vary with different configurations.
  • The flashing display issue was experienced in 2008 with older equipment models.
  • One reported case of a defective Dionic 90 with failed internal electronics does not necessarily represent a common manufacturing problem.
  • No discussion of whether undersized cabling contributes to overcurrent conditions beyond the battery rating itself.
Read the original threadAsk about this threadThe answer cites the archive