SteadiHub
2019General Discussion forum

Arri LF camera experiencing random power-downs and reboots during production

What the thread found

  • A camera powered down and rebooted intermittently during a fourteen-week shoot, particularly when not actively rolling or between setups, and the issue persisted across two different camera bodies
  • Voltage drops from auxiliary electronics powering up can trigger camera reboots even if the drop lasts only milliseconds, as the camera interprets this as a power loss
  • Similar power cycling issues have been reported with other camera models when combining them with rig electronics like inverters running at different voltages
  • The problem occurred on rigs powered by batteries as well as by external power blocks
  • Exhaustive wiring inspection by a service center found no identifiable faults in the rig's cabling or connections

Depends on

  • The root cause was never definitively identified or resolved in this case
  • No confirmation that jumper block configuration actually resolved the power issues, only that one configuration was used without problems
  • Whether the issue is specific to certain PRO rig versions or electronics combinations remains unclear
  • The role of the Teradek transmitter power draw in contributing to voltage instability was not investigated
Read the original threadAsk about this threadThe answer cites the archive