Preston HU3 follow focus screen not powering on
12 years old. Gear and prices may have changed since.
What the thread found
- A loose ribbon cable inside the Preston HU3 unit can prevent the display from turning on when powered.
- Reseating the ribbon cable by pushing it firmly into its connector typically resolves the screen power issue.
- Checking all other internal connectors while addressing the ribbon cable issue is recommended to prevent similar problems.
- The fix can be completed without contacting manufacturer support by carefully opening the unit and reseating connectors.
Depends on
- The discussion mentions a monochrome OLED screen prone to burn-in but does not detail if this is related to the power-on problem.
- Caution is needed when handling the ribbon cable as it can be damaged during the repair process.
- Only one user confirmed successful resolution using this method.
Gear in this thread
Parts
Same gear or parts
- 2026Pulling focus and zoom yourself while operating, especially on live showsOperator practice
- 2026Swapping an ARRI ALEXA 35 between tripod/studio and Steadicam® mounting: baseplate choice and fastest workflow.FacebookSteadicam operators group
- 2025LC-1 (Lens Control-1) follow focus system: wired architecture, motors, and early operational experience (1990s).FacebookThe Steadicam Group
- 2024Modifications to a Steadicam Scout rig for expanded power distribution and connectivityGeneral Discussion